products1

Yonker E10 Ecg Etco2 Hospitalis Modular Patient Monitor

Description:

E serie Yonker estmodularis patientes monitordisposito ICU, CCU et OR.E10 designatus est ut dimidium obturaculum in monitore, patiens modularis monitor praebet ut solutiones plurium lectionum curam sanitatis comprehensivam praebeat.
Monitor aeger modularis amplis parametris simul monitorem capere potest, accommodans a vigilantia ad curas criticas generales, additis vigilantia facultatibus inclusis ETCO2 et dualis IBP.

 

Configurationis libitum:
Nellcor SpO2, masimo SpO2, dual IBP, ETCO2, tactus velum, scelerisque printer NELLCOR

 

Applicatio:
YonkerE10 aeger monitor aptus est ad operandum cubiculum, custodiam, ICU, CCU, outpatientem, lectum vigilantem et alia applicationis missionum.Et idonei sunt neonati, pueri, adulti, senes et alii generis hominum.

 

Qualitas Certification: CE

Lingua: Anglica, Hispanica, Portugallia, Polonia, Russica, Turcica, Gallica, Italica

DeliveryStock bona amet intra LXXII horis

Warranty: Annis II


Product Detail

FRUCTUS SPECIFICATIONUM

OPERA & Support

FEEDBACK

Product Tags

 

 

 

 

1. 8 parametri (SpO2, PR, NIBP, ECG, RESP, TEMP ) , Nellcor SpO2, Masimo SpO2, Dual IBP, ETCO2, Tange velum, Thermal printer NELLCOR;
2. 10 inch altum resolutio color TFT LCD ostentus;
3. Plenus tactus velamentum selectabile, operationi aptius;

medical patient monitor E10 (1)
monitor in hospital

 

 

 

 

4. Tempus reale ST segmentum analysis, deprehensio gradatim facta;
6. Patient info input administratione functionis;
7. Resistentia efficiens ad impedimentum defibrillatoris et HF cultelli;
8. Inaedificata alta capacitas lithium altilium (4 horae) pro subitis potentiae eu vel patientis translationis;
9. 400 circulos NIBP indicem, 6000 secundis ECG waveforms recall, 60 terror evens records recall, 7-day trend chart in storage;
10. Flexibile agunt functiones ETCO2 et duales IBP;

 

 

 

 

11. Diagnosis, vigilantia, surgery tres modi vigilantiae, sustenta filum seu systema centrale wireless centralis;
12. 3 level audio / terror visuales function ;
13. urgere tres modi vigilantes, sustenta filum vel systema centrale wireless centralis;
14. Modularis aegrotus monitor, flexibilis ad diversa vigilantia requisita.

hospital room monitor E10
07
H98ef2d3ff3d64018a20bfeccd2c7a2f0f
710

  • Previous:
  • Deinde:

  • Qualitas signa et ClassificationCE, ISO13485SFDA: Classis bAnti-electroshock gradus: Classis armorum (potestas interna copia)

    TEMP/SpO 2 /NIBP: BF

    ECG/Resp: CF

    Applicationem dolor

    Adult/Pediatric/neonatal/Medicine/Male/

    Operating volutpat/ICU/CCU

    Ostendere

    10", 12.1", 15" color verus TFT tactus screen

    Environment

    Operans environment:

    Temperatus: 0 ~ 40

    Umor: ≤85%

    Altitude: -500 ~ 4600m

    Traiciendam et repono environment:

    Temperature: -20~ 60

    Umor: ≤93%

    Altitude: -500~ 13100m

    Potentia Requirements

    AC: 100 ~ 240V, 50Hz/60Hz

    DC: inaedificata rechargeable eu altilium

    Pugna: 4000mA 11.1V Lithium altilium

    2h operating post plenam causam (una)

    5min operating cum low altilium terrorem

    Dimensio et pondus

    Apparatus:

    E10: 271 mm × 158 mm ×286 mm;3.31 kg

    E10: 380 mm ×350 mm × 300 mm;5.6 kg

    Date PRAECLUSIO

    Trend diagram/table: 7x24h

    NIBP recensio: 400 events

    Unda recensio: 100min

    Terrorem review: 100 terror eventus

    Support medicamento concentration titration analysis

    ECG

    5 Ducit: RA, LA, LL, RL, V

    Modus duc: Ⅰ, , , aVR, aVL, aVF, V

    Auge: ×250,×500,×1000,×2000

    Sensibilitas: > 200 uV (Peak-ad apicem valorem)

    Impedimentum input: > 5 ( megohm )

    Sed: Surgery:1 ~ 20 Hz

    Monitor: 0.5 ~ 40 Hz

    Diagnostic: 0.05 ~ 130 Hz

    CMRR: ≥ 100dB

    Polarizationis intentione: ± 300mV

    Baseline, revocata tempus: post defibrillation <III secundis

    Signum dolor: 8 mV(Peak-ad apicem valorem)

    Calibrating signum: 1mV, praecisio ±5%

    ST Segmentum

    ST Segmentum Range: -2.0mV ~ +2.0mV

    Sagaciter: 0.02mV

    RESP

    Modus: RA-LL impedimentum

    Resp Impedimentum range: 0.3 ~ 3 Ω

    Base Impedimentum range: 200 Ω~ 4000 Ω

    Sed: 0.1 ~ 2.5Hz

    Resp rate: Adult: 0 ~ 120BrPM

    Neonatales/Pediatric: 0 ~ 150BrPM

    Consilium: 1BrPM

    Subtilitas: ± 2 BrPM

    Asphyxia metum: 10~40 seconds

    NIBPMethod: Pulsus fluctus oscillometeryWork modus: Manual / Auto / STAT

    Auto temporis modum metiri:

    1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)

    Tempus STAT Modus mensuræ: V minuta

    PR range: 40 ~ 240bpm

    Metire & terrorem range:

    Adultus: SYS 40 ~ 270mmHg

    DIA 10 ~ 215mmHg

    SALVIS 20 ~ 235mmHg

    Pediatrica: SYS 40 ~ 200mmHg

    DIA 10 ~ 150mmHg

    SALVIS 20~ 165mmHg

    Neonatales: SYS 40 ~ 135mmHg

    DIA 10 ~ 100mmHg

    INTELLECTUS XX ~ 110mmHg

    Static pressura range: 0 ~ 300mmHg

    Subtilitas: ± 3mmHg

    Pressura subtilitas:

    Maximilianus.mediocris error: ± 5mmHg

    Maximilianus.vexillum digredior: ± 8mmHg

    Tutela Overvoltage:

    Adultus: 300mmHg

    Pediatrica: 240mmHg

    Neonatales: 150mmHg

    SpO2

    Range: 0~ 100%

    Consilium: 1%

    Subtilitas: 70% ~ 100%: ±2 DIGIT

    0% ~ 69%: ± nulla definitio posita

    Rate pulsus

    Range: 20 ~ 300bpm

    Resolutio: 1bpm

    Subtilitas: ±3bpm

    TEMP

    Channel: 2

    Metire & terrorem range: 0 ~ 50

    Resolutio: 0.1

    Subtilitas (non sensorem): ± 0.1

    Latin Accessories

    1. NIBP colaphos & tube

    2. ECG cable & electrodes

    3. SpO2 sensorem

    4. TEMP probe

    5. Lithium-ion

    6. Power funem

    7. operans manual

    Libitum

    1. CO2 moduli

    2. IBP modulus

    3. Trolley bracket

    4. Tentorium bracket

    5. Monitor commentariis

    IBP

    Label ART, PA, CVP, RAP, LAP, ICP, P1, P2

    Mensuratio et terror range

    ART: 0 ~ 300 mmHg

    PA: -6 ~ 120 mmHg

    CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

    P1/P2: -10 ~ 300 mmHg

    Press Sensor

    Sensivity: 5 uV/V/mmHg

    Impedimentum: 300-3000Ω

    Resolutio: 1 mmHg

    Accuracy: ±2% vel ±1mmHg, quae magna

    Intervallum actualisation: about 1 Sec.

    CO2

    Parte / Main stream

    Effusio technicae mensurae infrared radialis

    mensurae ambitus: 0 ~ 99mmHg

    Subtilitas: 0~40mmHg±2mmHg

    41 ~76mmHg±5mmHg

    77~99mmHg±10mmHg

    Resolutio: 1mmHg

    Pumping rate: 70ml/min, 100ml/min

    Accuracy: 15% or 15ml/min big

    AwRR range: 0 ~ 120BrPM

    Subtilitas: 0 ~ 70BrPM: ±2BrPM

    >70BrPM:±5BrPM

    1.Quality Assurentia
    Strictioris qualitatis signa ISO9001 moderantia ut altissimae qualitatis curet;
    Responde qualitates intra 24 horas, et VII diebus redire gaude.

    2.Warranty
    Omnes producti habent warantum unum annum 1 de thesauro nostro.

    3.Deliver tempore
    Pleraque bona intra 72 horas post mercedem amet.

    4.Three packagings eligere
    Habes specialem 3 dotem capsulam packaging optiones pro singulis productis.

    5.Design Facultates
    Artwork / Instructio manual / productum consilium secundum exigentiam elit.

    6.Customized Logo et Packaging
    1. Silk-screen printing logo (Min. order.200 pcs);
    2. Laser insculptus logo (Min. order.500 pcs);
    3. Color box Package / polybag Package (Min. order.200 pcs).

    微信截图_20220506110630

    Related Products